ABSTRACT
The postural sway in 24 subjects performing a boresight calibration task on a large format head-up display is studied to estimate the impact of human limits on boresight calibration precision and ultimately on static registration errors. The dependent variables, accumulated sway path and omni-directional standard deviation, are analyzed for the calibration exercise and compared against control cases where subjects are quietly standing with eyes open and eyes closed. Findings show that postural stability significantly deteriorates during boresight calibration compared to when the subject is not occupied with a visual task. Analysis over time shows that the calibration error can be reduced by 39% if calibration measurements are recorded in a three second interval at approximately 15 seconds into the calibration session as opposed to an initial reading. Furthermore parameter optimization on experiment data suggests a Weibull distribution as a possible error description and estimation for omni-directional calibration precision. This paper extends previously published preliminary analyses and the conclusions are verified with experiment data that has been corrected for subject inverted pendulum compensatory head rotation by providing a better estimate of the position of the eye. With correction the statistical findings are reinforced.
- Ahmadi, H., Shams, P., Davies, N., Joshi, N., and Kelly, M. 2007. Age-related changes in the normal sagittal relationship between globe and orbit. Journal of Plastic, Reconstructive & Aesthetic Surgery 60, 246--250.Google ScholarCross Ref
- Axholt, M., Peterson, S., and Ellis, S. R. 2008. User boresighting for ar calibration: A preliminary analysis. In Proceedings of IEEE Virtual Reality, p 43--46.Google Scholar
- Azuma, R., and Bishop, G. 1994. Improving static and dynamic registration in an optical see-through hmd. In Proceedings of SIGGRAPH '94, 197--204. Google ScholarDigital Library
- Caudell, T. P., and Mizell, D. W. 1992. Augmented reality: An application of head-up display technology to manual manufacturing processes. In Proceedings of Hawaii International Conference on System Sciences, 659--669.Google Scholar
- Chambers, J. M., Cleveland, W. S., Kleiner, B., and Tukey, P. A. 1983. Graphical Methods of Data Analysis. Duxbury Press, Belmont, California.Google Scholar
- Collins, J., and Luca, C. D. 1993. Open-loop and closed-loop control of posture: A random-walk analysis of center-of-pressure trajectories. Exp Brain Res 95, 308--318.Google ScholarCross Ref
- Collins, J., and Luca, C. D. 1994. Random walking during quiet standing. Physical Review Letters 73, 5 (August), 764--767.Google ScholarCross Ref
- Ditchburn, R., and Ginsberg, B. 1952. Vision with a stabilized retinal image. Nature 170, 36--38.Google ScholarCross Ref
- Donker, S. F., Roerdink, M., Greven, A. J., and Beek, P. J. 2007. Regularity of center-of-pressure trajectories depends on the amount of attention invested in postural control. Exp Brain Res 181, 1--11.Google ScholarCross Ref
- Duarte, M., and Zatsiorsky, V. M. 2001. Long-range correlations in human standing. Physics Letters A 283, 124--128.Google ScholarCross Ref
- Elliott, C., and Murray, A. 1998. Repeatability of body sway measurements; day-to-day variation measured by sway magnetometry. Physiological Measurements 19, 159--164.Google ScholarCross Ref
- Elliott, C., FitzGerald, J. E., and Murray, A. 1998. Postural stability of normal subejcts measured by sway magnetometry: pathlength and area for the age range 15 to 64 years. Physiological Measurements 19, 103--109.Google ScholarCross Ref
- Ellis, S. R. 2006. Towards determination of visual requirements for augmented reality displays and virtual environments for the airport tower. In Proceedings of the NATO Workshop on Virtual Media for the Military, no. HFM-121/RTG 042 HFM-136, 31-1--31-10.Google Scholar
- Gage, W. H., Winter, D. A., Frank, J. S., and Adkin, A. L. 2004. Kinematic and kinetic validity of the inverted pendulum model in quiet standing. Gait and Posture 19, 124--132.Google ScholarCross Ref
- Guerraz, M., Sakellari, V., and Burchill, P. 2000. Influence of motion parallax in the control of spontaneous body sway. Experimental Brain Research 131, 2 (March), 244--252.Google ScholarCross Ref
- Gullstrand, A. 1909. Physiologic Optics, 3rd ed., vol. 1. 350--358.Google Scholar
- Holloway, R. L., 1997. Registration error analysis for augmented reality. Presence: Teleoperators and Virtual Environments 6(4) (August 1997), pp. 413--432.Google Scholar
- Howells, W. W. 1989. Skull Shapes and the Map: Craniometric Analyses in the Dispersion of Modern Homo. Peabody Museum of Archaeology and Ethnology, Harvard University, Cambridge, Massachusets. Distributed by Harvard University Press.Google Scholar
- Janin, A. L., Mizell, D. W., and Caudell, T. P. 1993. Calibration of head-mounted displays for augmented reality applications. In Proceedings of IEEE VRAIS '93, pp. 246--255.Google Scholar
- Nicholson, R. M. 1966. The feasibility of helmet-mounted sight as a control device. Human Factors 8, 417--425.Google ScholarCross Ref
- Peterson, S., Axholt, M., and Ellis, S. R. 2007. Very large format stereoscopic head-up display for the airport tower. In Proceedings of the Virtual Images Seminar, CNRS/Renault, no. 16.Google Scholar
- Riggs, L., Ratliff, F., Cornsweet, J., and Cornsweet, T. 1953. The dissappearance of steadily fixated visual test objects. Journal of the Optical Society of America 43, 495--501.Google ScholarCross Ref
- Smith, S. D., and Smith, J. A. 2006. Head and helmet biodynamics and tracking performance in vibration environments. Aviation, Space, and Environmental Medicine 77 (April), 388--397. Also published as interim report ARL-HE-WP-JA-2006-0005 at the USA Air Force Research Laboratory.Google Scholar
- Tuceryan, M., and Navab, N. 2000. Single point active alignment method (spaam) for optical see-through hmd calibration for ar. In In Proceedings of IEEE and ACM International Symposium on Augmented Reality.Google Scholar
- Verona, R. W. 1978. Head aiming/tracking accuracy in a helicopter environment. In AGARD Conference Proceedings, NATO, USA Airforce Research Laboratory (USAARL) P.O. Box 577, Fort Rucker, Al 36362, USA, S. Knapp, Ed., no. 255, Advisory Group for Aerospace Research and Development, 51:1--51:18.Google Scholar
- Wells, M. J., and Griffin, M. J. 1987. A review and investigation of aiming and tracking performance with head-mounted sights. IEEE Transactions on Systems, Man, and Cybernetics SMC-17, 2 (March/April), 210--221. Google ScholarDigital Library
- Woollacott, M., and Shumway-Cook, A. 2002. Attention and the control of posture and gait: a review of an emerging area of research. Gait and Posture 16, 1--14.Google ScholarCross Ref
Index Terms
- User boresight calibration precision for large-format head-up displays
Recommendations
Comparing a friction-based uni-directional treadmill and a slip-style omni-directional treadmill on first-time HMD-VR user task performance, cybersickness, postural sway, posture angle, ease of use, enjoyment, and effort
Highlights- Uni-directional and omni-directional treadmills significantly increase cybersickness symptoms in HMD-VR users after 10 min.
- Omni-directional treadmills increase cybersickness symptoms in HMD-VR users significantly more than uni-...
AbstractTreadmills allow users to translate their real world walking into movement in virtual worlds. Conventional treadmills used for fitness can be repurposed for users to move around in virtual reality, but permit walking in only one direction (uni-...
Multi-position Outfield Calibration for Laser Gyro Strapdown Inertial Navigation System
ICECC '12: Proceedings of the 2012 International Conference on Electronics, Communications and ControlIt is important to calibrate the errors of sensors to improve the performance level of laser gyro strap down inertial navigation system (SINS). In this paper, a calibration method that is suitable for practical application in the outfield is presented ...
Analysis and calibration on installation errors of accelerometer in GFSINS
CCDC'09: Proceedings of the 21st annual international conference on Chinese control and decision conferenceAim at the precision limitation for calculating angular velocity because of installation errors of accelerometer in the gyro free strapdown inertial navigation system (GFSINS), a calibration method of installation error parameters is put forward. Based ...
Comments