Noise Aware Scheduling in Data Centers

Published: 01 June 2016 Publication History

Abstract

As the demand for large scale computing is rapidly increasing to serve billions of users across the world, more powerful and densely packed server configurations are being used. Often in developing countries, and in small and medium enterprises, it is hard to place such servers in sound-proof server rooms. Hence, servers are typically placed in close proximity to employees. The noise from the cooling fans in servers adversely affects employees' health, and reduces their productivity. In this paper, we provide a framework for computer architects to measure the acoustic profile in a data center along with the temperature profile, and estimate the sound power levels at points of interest. Additionally, we studied the noise levels obtained upon using algorithms targeted at homogenizing the temperature profile. We found that these algorithms result in high noise levels, sometimes above the permissible levels. So, we propose two heuristics to redistribute workloads in a data center such that noise can be reduced at certain target locations. We obtain a noise reduction of 2-13 dB when compared with uniform workload distribution, and upto 16 dB as compared to temperature aware workload placement, with a reduction of at least 5-6 dB in 75% of the cases. The performance overhead is limited to 1%.

References

[1]
T. ASHRAE, "9.9 (2011) thermal guidelines for data processing environments--expanded data center classes and usage guidance," Whitepaper prepared by ASHRAE technical committee (TC), vol. 9, 2011.
[2]
R. H. Lyon and A. E. Bergles, "Noise and cooling in electronics packages," Components and Packaging Technologies, IEEE Transactions on, vol. 29, no. 3, pp. 535--542, 2006.
[3]
C. E. Peterson. (2011) Dell enterprise acoustics. {Online}. Available: http://www.dell.com/downloads/global/products/pedge/en/acoustical-education-dell-enterprise-white-paper.pdf
[4]
OSHA. Noise exposure computation occupational safety and health standards 1910.95 app a. {Online}. Available: https://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=STANDARDS&p_id=9736
[5]
S. G. Kujawa and M. C. Liberman, "Adding insult to injury: cochlear nerve degeneration after "temporary noise-induced hearing loss," The Journal of Neuroscience, vol. 29, no. 45, pp. 14 077--14 085, 2009.
[6]
S. Klitzman and J. M. Stellman, "The impact of the physical environment on the psychological well-being of office workers," Social Science & Medicine, vol. 29, no. 6, pp. 733--742, 1989.
[7]
M. Kassner. (2014) Data centers may be hazardous to your hearing. {Online}. Available: http://www.techrepublic.com/article/data-centers-may-be-hazardous-to-your-hearing/
[8]
T. S. Dope. (2012) Hearing loss from data center work. {Online}. Available: http://boards.straightdope.com/sdmb/showthread.php?t=672967
[9]
Edugeek. (2011) Working environment - server noise. is this affecting my hearing? {Online}. Available: http://www.edugeek.net/forums/general-chat/86747-working-environment-server-noise-affecting-my-hearing.html
[10]
P. Thibodeau. (2007) That sound you hear? the next data center problem. {Online}. Available: http://www.infoworld.com/article/2642787/operating-systems/that-sound-you-hear--the-next-data-center-problem.html
[11]
(2010) Web hosting talk, data center noise cancellation. {Online}. Available: http://www.webhostingtalk.com/showthread.php?t=958922
[12]
Health and S. Executive. Hse - noise: Frequently asked questions. {Online}. Available: http://www.hse.gov.uk/noise/faq.htm#q5
[13]
(2014) Are noise cancelling headphones worth it? {Online}. Available: http://www.forbes.com/sites/geoffreymorrison/2014/02/21/are-noise-cancelling-headphones-worth-it/#1c3222b97e26
[14]
S. Z. Jalilzadeh, M. Asgari, and M. E. Sadeghi, "A quantitative noise survey in a general room--based data center," International Journal of Occupational Hygiene, vol. 6, no. 1, pp. 16--22, 2014.
[15]
S. Sommerfeldt, M. Maughan, J. Daily, J. Esplin, Z. Collins, and M. Shaw, "Acoustical analysis of active control in the server room of a c7 data centers colocation facility," Feasibility Report, Brigham Young University, 2010.
[16]
(2015) Datacenter hearing protection. {Online}. Available: https://www.reddit.com/r/networking/comments/1wuq9i/datacenter_hearing_protection/
[17]
(2015) Hearing protection for data centre work. {Online}. Available: https://www.reddit.com/r/sysadmin/comments/2xckqr/hearing_protection_for_data_centre_work/
[18]
(2015) Bluetooth headset for use in a data center. {Online}. Available: https://www.reddit.com/r/networking/comments/3l28dy/bluetooth_headset_for_use_in_a_data_center/
[19]
(2015) What type of headset works well in data centers? {Online}. Available: https://www.reddit.com/r/sysadmin/comments/316tve/what_type_of_headset_works_well_in_data_centers/
[20]
(2015) Do noise cancelling headphones lessen hearing damage? {Online}. Available: https://www.reddit.com/r/audiophile/comments/2t19ma/_do_noise_cancelling_headphones_lessen_hearing/
[21]
(2015) Psa: Your beats noise canceling headphones aren't proper earpro. {Online}. Available: https://www.reddit.com/r/guns/comments/28wn8b/psa_your_beats_noise_canceling_headphones_arent/
[22]
(2015) Google data center. {Online}. Available: https://www.reddit.com/r/Cyberpunk/comments/19jvhw/google_data_center/
[23]
Health and S. Executive. Hse - noise: Hearing protection. {Online}. Available: http://www.hse.gov.uk/noise/hearingprotection.htm
[24]
OSHA. (2014) Safety and health topics | occupational noise exposure. {Online}. Available: https://www.osha.gov/SLTC/noisehearingconservation/
[25]
P. Artman and C. E. Peterson. Advanced thermal control: Optimizing across environments and power goals. {Online}. Available: http://www.dell.com/downloads/global/products/pedge/advanced_thermal_control_whitepaper.pdf
[26]
HP. Hp proliant microserver gen8. {Online}. Available: http://www8.hp.com/us/en/products/proliant-servers/product-detail.html?oid=5379860
[27]
IBM. Ibm system x3100 m4 - features and benefits. {Online}. Available: http://www-03.ibm.com/systems/in/x/hardware/tower/x3100m4/features.html
[28]
Fujitsu. Fujitsu server primergy tower systems - fujitsu global. {Online}. Available: http://www.fujitsu.com/global/products/computing/servers/primergy/tower/
[29]
APC. Server cabinets - virtually silent, sound proofed server cabinet solutions. {Online}. Available: http://www.kellsystems.com/
[30]
GIZMAC. Xrackpro2 noise reducing server racks rackmout enclosure cabinets. {Online}. Available: http://www.xrackpro.com/
[31]
Orion. Acoustic racks. {Online}. Available: http://www.rackcabinets.co.uk/cabinets/acoustic-racks.html
[32]
A. Products. Silence server noise - quiet acoustic rack enclosures, soundproof materials. {Online}. Available: http://www.acoustiproducts.com/en/index.asp
[33]
Serverfault. How can you reduce ambient noise from servers? {Online}. Available: http://serverfault.com/questions/265540/how-can-you-reduce-ambient-noise-from-servers
[34]
(2012) What can be done to control noise levels in data centers? {Online}. Available: http://www.idganswers.com/question/3607/what-can-be-done-to-control-noise-levels-in-data-centers
[35]
(2015) Making noise about a quiet data center. {Online}. Available: http://blogs.cisco.com/ciscoit/b-dc-03112015-making-noise-about-a-quiet-data-center
[36]
(2014) Quieter data center. {Online}. Available: http://www.pducables.com/kens-korners/2014/12/quieter-data-center/
[37]
(2014) How to reduce data center noise? {Online}. Available: https://storageservers.wordpress.com/2014/01/10/how-to-reduce-data-center-noise/
[38]
(2014) To lower the noise levels in data centers, raise the temperature. {Online}. Available: http://www.itwatchdogs.com/environmental-monitoring-news/data-center/to-lower-the-noise-levels-in-data-centers,-raise-the-temperature-617409
[39]
(2015) Noise reduction - asetek. {Online}. Available: http://www.asetek.com/data-center/technology/data-center-benefits/noise-reduction/
[40]
S. Wynne. (2011) How are you handling excessive noise in the data center? {Online}. Available: http://blog.rackmountsolutions.net/soundproof-server-rack/how-are-you-handling-excessive-noise-in-the-data-center/
[41]
P. Thibodeau. (2007) That sound you hear? the next data center problem | computerworld. {Online}. Available: http://www.computerworld.com/article/2542868/data-center/that-sound-you-hear--the-next-data-center-problem.html
[42]
M. F. Bari, R. Boutaba, R. Esteves, L. Z. Granville, M. Podlesny, M. G. Rabbani, Q. Zhang, and M. F. Zhani, "Data center network virtualization: A survey," Communications Surveys & Tutorials, IEEE, vol. 15, no. 2, pp. 909--928, 2013.
[43]
U. Iemma and V. Marchese, "AcouSTO, Acoustics Simulation TOol v1.6," http://acousto.sourceforge.net, 2014.
[44]
(2016) Appendix of noise aware scheduling in data centers. {Online}. Available: http://www.cse.iitd.ac.in/~srsarangi/tr/noise/appendix.pdf
[45]
I. Acentech. (2014) Acoustics & vibration fundamentals. {Online}. Available: http://www.acentech.com/resources/fundamentals.html
[46]
A. G. Carol. (2014) The relationship of voltage, loudness, power and decibels. {Online}. Available: http://www.gcaudio.com/resources/howtos/voltageloudness.html
[47]
R. Ayoub and T. S. Rosing, "Cool and save: cooling aware dynamic workload scheduling in multi-socket cpu systems," in ASP-DAC, 2010, 2010, pp. 891--896.
[48]
J. D. Moore, J. S. Chase, P. Ranganathan, and R. K. Sharma, "Making scheduling" cool": Temperature-aware workload placement in data centers." in USENIX, General Track, 2005, pp. 61--75.
[49]
R. K. Sharma, C. E. Bash, C. D. Patel, R. J. Friedrich, and J. S. Chase, "Balance of power: Dynamic thermal management for internet data centers," Internet Computing, IEEE, vol. 9, no. 1, pp. 42--49, 2005.
[50]
N. Vasic, T. Scherer, and W. Schott, "Thermal-aware workload scheduling for energy efficient data centers," in International Conference on Autonomic Computing, 2010, pp. 169--174.
[51]
VMWare. (2013) vmotion. {Online}. Available: http://www.vmware.com/products/vsphere/features/vmotion
[52]
R. Ayoub, S. Sharifi, and T. S. Rosing, "Gentlecool: Cooling aware proactive workload scheduling in multi-machine systems," in DATE, 2010, 2010, pp. 295--298.
[53]
S. Akoush, R. Sohan, A. Rice, A. W. Moore, and A. Hopper, "Predicting the performance of virtual machine migration," in MASCOTS, 2010, 2010, pp. 37--46.
[54]
C. Clark, K. Fraser, S. Hand, J. G. Hansen, E. Jul, C. Limpach, I. Pratt, and A. Warfield, "Live migration of virtual machines," in Symposium on Networked Systems Design & Implementation-Volume 2, 2005, pp. 273--286.
[55]
X. Jiang, F. Yan, and K. Ye, "Performance influence of live migration on multi-tier workloads in virtualization environments," IARIA CLOUD, pp. 72--81, 2012.
[56]
A. Icepak, "14.0 documentation," ANSYS Inc, 2012.
[57]
A. Fluent, "12.0 documentation," Ansys Inc, 2009.
[58]
D. C. Journal. (2013) Raising data center power density. {Online}. Available: http://www.datacenterjournal.com/it/raising-data-center-power-density/
[59]
D. C. U. Group. (2013) Data center users' group. {Online}. Available: http://datacenterug.ning.com/
[60]
E. N. Power. (2013) Average power density per rack holds at 5.94 kw. {Online}. Available: http://www.emersonnetworkpower.com/en-US/Solutions/infographics/Pages/graphicoftheweek18.aspx
[61]
C. Geuzaine and J.-F. Remacle, "Gmsh: A 3-d finite element mesh generator with built-in pre-and post-processing facilities," International Journal for Numerical Methods in Engineering, vol. 79, no. 11, pp. 1309--1331, 2009.
[62]
C. Bienia, S. Kumar, J. P. Singh, and K. Li, "The parsec benchmark suite: characterization and architectural implications," in PACT, 2008.
[63]
I. Dell. (2011) Dell poweredge r710 power and performance data sheet. {Online}. Available: http://www.dell.com/downloads/global/products/pedge/en/Dell%20PowerEdge_R710_570W_Energy_Star_Data_Sheet_new.pdf
[64]
C. E. Leiserson, R. L. Rivest, C. Stein, and T. H. Cormen, Introduction to algorithms. MIT press, 2001.
[65]
I. Dell. (2011) Poweredge r710 technical guide. {Online}. Available: http://www.dell.com/downloads/global/products/pedge/en/server-poweredge-r710-tech-guidebook.pdf
[66]
(2015) Spire sound level measurements: Which heatsink is quietest? {Online}. Available: http://www.frostytech.com/articleview.cfm?articleid=2521&page=3
[67]
(2005) Acoustics/noise from cooling fans. {Online}. Available: http://en.wikibooks.org/wiki/File:Noisespectrum.gif

Cited By

View all
  • (2024)Acoustics Analysis of Air and Hybrid Cooled Data Center2024 23rd IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)10.1109/ITherm55375.2024.10709368(1-11)Online publication date: 28-May-2024
  • (2022)Potential Health Impacts of Gamma-Frequency Sound in Server RoomWSEAS TRANSACTIONS ON SIGNAL PROCESSING10.37394/232014.2022.18.718(51-59)Online publication date: 2-Apr-2022
  • (2022)Multiphysics Thermal-Acoustic Modeling of a Server in a Data Center2022 21st IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (iTherm)10.1109/iTherm54085.2022.9899616(1-7)Online publication date: 31-May-2022

Recommendations

Comments

Information & Contributors

Information

Published In

cover image ACM Conferences
ICS '16: Proceedings of the 2016 International Conference on Supercomputing
June 2016
547 pages
ISBN:9781450343619
DOI:10.1145/2925426
Permission to make digital or hard copies of all or part of this work for personal or classroom use is granted without fee provided that copies are not made or distributed for profit or commercial advantage and that copies bear this notice and the full citation on the first page. Copyrights for components of this work owned by others than ACM must be honored. Abstracting with credit is permitted. To copy otherwise, or republish, to post on servers or to redistribute to lists, requires prior specific permission and/or a fee. Request permissions from [email protected]

Sponsors

Publisher

Association for Computing Machinery

New York, NY, United States

Publication History

Published: 01 June 2016

Permissions

Request permissions for this article.

Check for updates

Qualifiers

  • Research-article
  • Research
  • Refereed limited

Conference

ICS '16
Sponsor:

Acceptance Rates

Overall Acceptance Rate 629 of 2,180 submissions, 29%

Contributors

Other Metrics

Bibliometrics & Citations

Bibliometrics

Article Metrics

  • Downloads (Last 12 months)14
  • Downloads (Last 6 weeks)2
Reflects downloads up to 09 Mar 2025

Other Metrics

Citations

Cited By

View all
  • (2024)Acoustics Analysis of Air and Hybrid Cooled Data Center2024 23rd IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm)10.1109/ITherm55375.2024.10709368(1-11)Online publication date: 28-May-2024
  • (2022)Potential Health Impacts of Gamma-Frequency Sound in Server RoomWSEAS TRANSACTIONS ON SIGNAL PROCESSING10.37394/232014.2022.18.718(51-59)Online publication date: 2-Apr-2022
  • (2022)Multiphysics Thermal-Acoustic Modeling of a Server in a Data Center2022 21st IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (iTherm)10.1109/iTherm54085.2022.9899616(1-7)Online publication date: 31-May-2022

View Options

Login options

View options

PDF

View or Download as a PDF file.

PDF

eReader

View online with eReader.

eReader

Figures

Tables

Media

Share

Share

Share this Publication link

Share on social media